Power Distribution Transformer, Electrical transformer, Servo Voltage Stabilizer Manufacturer https://saielectricals.com Wed, 26 Aug 2020 10:45:45 +0000 en-US hourly 1 https://wordpress.org/?v=4.6.29 Listing of blogs on Servo Voltage Stabilizer https://saielectricals.com/2017/03/listing-of-blogs-on-servo-voltage-stabilizer/ https://saielectricals.com/2017/03/listing-of-blogs-on-servo-voltage-stabilizer/#respond Sat, 25 Mar 2017 10:31:00 +0000
Servo Voltage Stabilizer experts at Sai Electricals have been releasing blogs on various topics for Servo Voltage Stabilizer. The blogs mainly cover following topics-
 
1.  Servo Voltage Stabilizer.
2. Automatic Power Factor Controller.
We give here below links for all the blogs published by Sai Electricals to enable you to acquire your desired information.
1.   Servo Voltage Stabilizer.
2.   Automatic Power Factor Controller.

In case any enquiry free feel to contact us at info@saielectricals.com or visit our website www.saielectricals.com
]]>
https://saielectricals.com/2017/03/listing-of-blogs-on-servo-voltage-stabilizer/feed/ 0
Install “POWERWARE” Voltage Stabilizer and Start Earning Form the Day One. https://saielectricals.com/2016/04/install-powerware-voltage-stabilizer-and-start-earning-form-the-day-one/ https://saielectricals.com/2016/04/install-powerware-voltage-stabilizer-and-start-earning-form-the-day-one/#respond Mon, 25 Apr 2016 06:14:00 +0000 http://saielectricals.com/2016/04/25/install-powerware-voltage-stabilizer-and-start-earning-form-the-day-one/
A voltage stabilizer, as the name suggests helps us to have a stabilized the voltage. When there is a high voltage then it makes it to the required level of electrical equipment and vice versa. Stabilized input to the machines helps us to increase the efficiency of machines as well as quality of final product improves.
Now we consider the two cases i.e over voltage and low voltage, in first case i.e in case when the voltage is higher than the voltage at which equipment is designed to operate most effectively. Due to this over voltage problem equipment lifetime will reduced and increases in energy consumption without any improvement in performance. Similarly in second case when the voltage goes on lower side than the required/ designed voltage, due to this problem number of problem will generate in equipment, for example contactors and relays may drop out which will be the reason for interruption in operation of machines.
Your expensive equipment is being subjected to undesirable stress because of improper voltage. Typical ill-effects on some common equipment are illustrated below.
Equipments
Effects of under voltage
Effects of over voltage
UPS Systems
Low Battery Life
Failure
Electronics
Malfunction
Failure
Electron Tubes
10% drop reduces Cathode emission by 40%
5% increase reduces tube life by 50%
Rectifier Loads
At 10 % under voltage, plating rate drops by 20%, charging rate Drops by 25%, welding time increased by 20%
Excessive heat generated, produces poor welds can reduce rectifier life substantially. Plating/deposition may be uncontrolled.
Motors/ Air Conditioning
Overload and uneven heating/ low efficiency.
Overheating
Lamps, Tube lights Heating Elements
Low lux, reduced efficiency.
Higher Failure/ high energy consumption due to over heating
Process Plants
Increase in wastage of finished product, stoppage of production
Uneven quality
Increase Productivity & Product Quality:
If you install POWERWARE Electronic Automatic Voltage Controller, an added advantage is increase in Productivity & quality. This is due to the fact that nuisance equipment breakdowns due to overheating will come under control & production will go on uninterrupted. Additionally, due to a well maintained voltage level, there will be no variations in process parameters leading to consistent quality.
Further efficiency of POWERWARE servo voltage stabilizer is approx. 98.5% as compared to competitors (even IS standard) which specifies only 95%. We give below the calculation to establish the additional potential saving Rs. 3,78,000/-   per year recurring, which will accrue to you using our high efficiency 500 KVA servo voltage stabilizer.
1.    Min. Guaranteed Eff. of POWERWARE SVS                           =          98.5 %
2.    Eff. of Other Make                                                                      =         95 %
3.    Difference is                                                                                =          3.5%
4.    Rating of the stabilizer                                                                =        500 KVA
5.    3.5 % of Rated Capacity                                                             =   3.5 % of 500 = 17.5 KVA
6.    Total Energy Difference = KVA DIFFERENCE X 12X300     =      63000 Units
7.    Cost of These Energy @ 6.00 per unit                                       =  Rs.3,78,000
So, We can observe from above that with the help of SVS we can prevent our costly equipments by voltage fluctuations as well as we can get huge saving on our yearly/ monthly energy bills.

POWERWARE Servo Voltage Stabilizer is the proven solution for all problems caused by voltage fluctuations and unbalance .It saves your costly equipments and processes from detrimental effects of fluctuating and unbalanced voltages and gives you mental peace to concentrate on more important business issues.
Our products find wide applications in industrial, commercial, residential, process plants power electronics, CNC machines etc. not only in the country but internationally also.
Key features of POWERWARE Servo Voltage Stabilizers are as below:
Energy Saver
Optimum Output
Complete Control
Suitable for unbalanced Loads
Detachable Panel
Easy mounting and dismantling
Can face any direction of use
Provides great facility for monitoring and control by keeping inside control room
Distortion less Waveform
Good Output quality
Digital Display
Easy to read and accurate
Good looks and helps in monitoring and control
Quick Response
Response time-10milli sec
Painting-Epoxy
PU (optional)
Good paint quality
Longer paint life in outdoor conditions
Quality Tests
Testing as per IS 2026 high Reliability
In case any enquiry feel free to contact us at info@saielectricals.com
]]>
https://saielectricals.com/2016/04/install-powerware-voltage-stabilizer-and-start-earning-form-the-day-one/feed/ 0
ISSUE OF BIS LICENSE FOR TRANSFORMER https://saielectricals.com/2016/03/issue-of-bis-license-for-transformer/ https://saielectricals.com/2016/03/issue-of-bis-license-for-transformer/#respond Tue, 01 Mar 2016 10:03:00 +0000 http://saielectricals.com/2016/03/01/issue-of-bis-license-for-transformer/
Sai Electricals is an ISO 9001-2008 certified company, professionally managed & promoted by technocrats from IIT Kanpur with over 3 decades of experience in efficient energy management & power conditioning. We are committed to reduce global warming by improving the quality of power & providing high energy efficiency through optimum selection of equipments., because we understand that losses due to poor power quality will not only be disastrous for your business, but also for the globe. 
Our computerized design of transformer gives the high efficiency as well as high reliability. We are also authorized by Bureau of Energy Efficiency for star rating transformers. Life of our Energy Efficient transformers got enhanced as these are operated on low temperatures due to low loss design.
Further we are pleased to inform to our customers that we have got BIS license vide license No. CM/L-8700024014 on Dtd. 20.01.2016.
Benefits to Customer from Energy Efficiency Level 1 BIS Approved Transformer
Efficiency of these transformers at 50% loading is more than 99.5% and at 100% loading efficiency is ranging between 98.5% to 99.1%. This transformer is highly cost effective when loading varies between no load to 100%.
]]>
https://saielectricals.com/2016/03/issue-of-bis-license-for-transformer/feed/ 0
HIGHLIGHTED POINTS FOR IS 1180 (Part 1) : 2014 https://saielectricals.com/2016/01/highlighted-points-for-is-1180-part-1-2014/ https://saielectricals.com/2016/01/highlighted-points-for-is-1180-part-1-2014/#respond Wed, 13 Jan 2016 08:56:00 +0000 http://saielectricals.com/2016/01/13/highlighted-points-for-is-1180-part-1-2014/
To improve the efficiency of our electrical system recently Bureau of Indian Standards has taken some major steps to improve the electrical network of our country and now from 1st Feb 2016 distribution transformer is added in mandatory equipment list of BIS and to manufacturing the transformer manufacturer must be obtained the license from BIS for this BIS issued the Fourth revision of IS 1180 (Part1): Outdoor Type Oil Immersed Distribution Transformers upto 2500kVA, 33KV Specification. In which BIS have been mentioned some major changes in the specification of transformers, some of the major highlighted points are as below:
In revised IS, transformers have been divided in three categories, which are as below:
a) Three phase distribution transformers upto and including 200KVA
b) Three phase distribution transformers higher than 200KVA upto and including 2500KVA
c) Single phase distribution transformers upto and including 25KVA
In revised IS specification, losses for each rating for each category have been defined in three levels which are denoted by as follows;
a) Energy Efficiency Level 1,
b) Energy Efficiency Level 2
3) Energy Efficiency Level 3
In each level maximum losses (No Load Loss + Load Loss) at 50% load & 100% load have been specified for each rating in all categories. Losses in Energy Efficiency Level 1 is almost equal to ECBC 2009 guidelines.
In revised IS 1180 there are three energy efficiency levels and for each categories, maximum values of total losses have been defined on 50% load and 100% load. Losses & percentage value of impedance for different categories are as below:
a) Three phase distribution transformers upto and including 200KVA, 11KV Class
Sl. No.
Rating (KVA)
% Z
Energy Efficiency Level 1
Energy Efficiency Level 2
Energy Efficiency Level 3
@ 50%
@ 100%
@ 50%
@ 100%
@ 50%
@ 100%
1
16KVA
4.5%
150W
480W
135W
440W
120W
400W
2
25KVA
4.5%
210W
695W
190W
635W
175W
595W
3
63KVA
4.5%
380W
1250W
340W
1140W
300W
1050W
4
100KVA
4.5%
520W
1800W
475W
1650W
435W
1500W
5
160KVA
4.5%
770W
2200W
670W
1950W
570W
1700W
6
200KVA
4.5%
890W
2700W
780W
2300W
670W
2100W
 
 
b) Three phase distribution transformers Higher than 200KVA upto and including 2500KVA, 11KV Class
Sl. No.
Rating (KVA)
% Z
Energy Efficiency Level 1
Energy Efficiency Level 2
Energy Efficiency Level 3
@ 50%
@ 100%
@ 50%
@ 100%
@ 50%
@ 100%
1
250KVA
4.5%
1050W
3150W
980W
2930W
920W
2700W
2
315KVA
4.5%
1100W
3275W
1025W
3100W
955W
2750W
3
400KVA
4.5%
1300W
3875W
1225W
3450W
1150W
3330W
4
500KVA
4.5%
1600W
4750W
1510W
4300W
1430W
4100W
5
630KVA
4.5%
2000W
5855W
1860W
5300W
1745W
4850W
6
1000KVA
5.0%
3000W
9000W
2790W
7700W
2620W
7000W
7
1250KVA
5.0%
3600W
10750W
3300W
9200W
3220W
8400W
8
1600KVA
6.25%
4500W
13500W
4200W
11800W
3970W
11300W
9
2000KVA
6.25%
5400W
17000W
5050W
15000W
4790W
14100W
10
2500KVA
6.25%
6500W
20000W
6150W
18500W
5900W
17500W
 
c) Single Phase distribution transformers upto and including 25KVA, 11KV Class
Sl. No.
Rating (KVA)
% Z
Energy Efficiency Level 1
Energy Efficiency Level 2
Energy Efficiency Level 3
@ 50%
@ 100%
@ 50%
@ 100%
@ 50%
@ 100%
1
5KVA
4.0%
40W
115W
35W
95W
30W
75W
2
10KVA
4.0%
70W
190W
60W
170W
55W
150W
3
16KVA
4.0%
95W
265W
82W
224W
63W
190W
4
25KVA
4.0%
125W
340W
110W
300W
95W
260W
Further to above it is also observed that IS 1180 are now also applicable for 22KV & 33KV class transformers, losses values for 22KV & 33KV class transformers shall be applicable as per below clause:
a) For transformers having voltage class above 11KV and upto and including 22KV, the permissible total loss value shall not exceed by 5% of the maximum total losses values mentioned in table a) & b) for three phase.
b)  For transformers having voltage class above 22KV and upto and including 33KV, the permissible total loss value shall not exceed by 7.5% of the maximum total losses values mentioned in table a) & b) for three phase.
c) For transformers having voltage class above 11KV and upto and including 22KV, the permissible total loss value shall not exceed by 7.5% of the maximum total losses values mentioned in table c) for single phase.
d)  For transformers having voltage class above 22KV and upto and including 33KV, the permissible total loss value shall not exceed by 10% of the maximum total losses values mentioned in table c) for single phase.
 
In case any enquiry feel free to contact us at info@saielectricals.com
]]>
https://saielectricals.com/2016/01/highlighted-points-for-is-1180-part-1-2014/feed/ 0
Listing of blogs on Transformer https://saielectricals.com/2015/11/listing-of-blogs-on-transformer/ https://saielectricals.com/2015/11/listing-of-blogs-on-transformer/#respond Tue, 24 Nov 2015 08:51:00 +0000 http://saielectricals.com/2015/11/24/listing-of-blogs-on-transformer/
Dear Sir,

Transformer experts at Sai Electricals have been releasing blogs on various topics for transformers. The blogs mainly cover following topics-

1.  Installation and Maintenance.
2. Protection of Transformers.
3. Standards and Energy Efficiency of Transformers.
4. Essentials and Selection Criteria of Transformers.
5. Corrugated Transformers and Compact Sub Stations.
We give here below links for all the blogs published by Sai Electricals to enable you to acquire your desired information.
1.   Installation and Maintenance.
2.   Protection of Transformers.
3.   Standards and Energy Efficiency of Transformers.
4.   Essentials and Selection Criteria of Transformers.
5.   Corrugated Transformers and Compact Sub Stations.

In case any enquiry free feel to contact us at info@saielectricals.com or visit our website www.saielectricals.com

]]>
https://saielectricals.com/2015/11/listing-of-blogs-on-transformer/feed/ 0
Heartfelt Wishes to our friends and followers on this joyful occasion of Eid Al-Azha. https://saielectricals.com/2015/09/heartfelt-wishes-to-our-friends-and-followers-on-this-joyful-occasion-of-eid-al-azha/ https://saielectricals.com/2015/09/heartfelt-wishes-to-our-friends-and-followers-on-this-joyful-occasion-of-eid-al-azha/#respond Thu, 24 Sep 2015 09:48:00 +0000 http://saielectricals.com/2015/09/24/heartfelt-wishes-to-our-friends-and-followers-on-this-joyful-occasion-of-eid-al-azha/

]]> https://saielectricals.com/2015/09/heartfelt-wishes-to-our-friends-and-followers-on-this-joyful-occasion-of-eid-al-azha/feed/ 0 ZERO DEFECT AND ZERO EFFECT https://saielectricals.com/2015/09/zero-defect-and-zero-effect/ https://saielectricals.com/2015/09/zero-defect-and-zero-effect/#respond Tue, 08 Sep 2015 09:27:00 +0000 http://saielectricals.com/2015/09/08/zero-defect-and-zero-effect/

Recently our Prime Minister Mr. Narendra Modi has been given a new slogan to our nation, “Don’t compromise on two points “Zero Defect” and “Zero Effect”.

Now Let’s think about this quote deeply we conclude that making our product which has ‘zero defect’ so that it does not come back (get rejected) from the market and ‘zero effect’ so that the manufacturing does not have an bad & worst effect on our environment”.


To achieve “Zero Defect” we have implemented the following:

A) Quality circles:

1) for identifying problems and providing solutions by Implementation of following:

2) Preparing cause and effect diagram

3) Pareto Analysis

4) Check sheets

5) Inter departmental customer satisfaction

B) Implementation of 5 S across plant.

C) Implementation of LEAN MANUFACTURING to reduce the wastages 

1) We are member of Lean manufacturing council under MSME Ministry Government of India.

2) Implemented ISO 9001 Quality System.

3) This initiative has reduced our wastages and delays by implementation of line balancing.

D) Use of computer aided design for reliable and defect free product.

Our Motto is:

“GREEN PRODUCT FROM GREEN PLANT FOR GREEN ENVIRONMENT”

A) We have reduced the carbon foot prints by using solar energy for oil processing and natural gas for heating ovens.
B) Water Harvesting.
C) No industrial waste is being drained out in environment.
D) By automated design using CAD we have been able to design products with lesser materials to reduce carbon foot prints.
E)   Power conditioning product i.e. Servo Voltage Stabilizer, Lighting, Isolation & Harmonic Offset Transformers and also manufacturing energy saving transformers as per Bureau of Energy Efficiency guidelines.

In case any enquiry free feel to contact us at info@saielectricals.com or visit our website www.saielectricals.com
]]>
https://saielectricals.com/2015/09/zero-defect-and-zero-effect/feed/ 0
Sai Electricals wish you “HAPPY RAKSHA BANDHAN” and I pray to God for your prosperous life. https://saielectricals.com/2015/08/sai-electricals-wish-you-happy-raksha-bandhan-and-i-pray-to-god-for-your-prosperous-life/ https://saielectricals.com/2015/08/sai-electricals-wish-you-happy-raksha-bandhan-and-i-pray-to-god-for-your-prosperous-life/#respond Fri, 28 Aug 2015 05:44:00 +0000 http://saielectricals.com/2015/08/28/sai-electricals-wish-you-happy-raksha-bandhan-and-i-pray-to-god-for-your-prosperous-life/

]]> https://saielectricals.com/2015/08/sai-electricals-wish-you-happy-raksha-bandhan-and-i-pray-to-god-for-your-prosperous-life/feed/ 0 SITE INSTRUCTIONS FOR TRANSFORMERS (PART 5) https://saielectricals.com/2015/08/site-instructions-for-transformers-part-5/ https://saielectricals.com/2015/08/site-instructions-for-transformers-part-5/#respond Wed, 26 Aug 2015 06:32:00 +0000 http://saielectricals.com/2015/08/26/site-instructions-for-transformers-part-5/

After successful installation it is very important to take care of the various safety measures during operation of transformer. Transformer ageing is very much depends upon various stresses like electrical i.e. loading patterns, surges & spikes, voltage & frequency variations, short circuit forces, over fluxing harmonic, mechanical, chemical and environmental factors which will affect the insulation of transformer and deteriorate the insulation this deterioration will affect the performance of transformer and reliability of equipment got reduced. Besides of theses stresses faults like partial discharge, electrical arcs, or hot spots generally deteriorate the condition of transformer in quick progression. Hence early detection of these faults is very important for saving transformer from any catastrophic failure.
Now a day’s various methods are available with us through which we can monitor and record the real time data for various parameters which are having a great impact on transformer performance, some of the parameters are as follows:
1) Internal Parameters
a) H2 PPM Level
b) Ambient Temperature
c) Oil Temperature
d) Winding Temperature Rise
2) External Parameters
a) Voltage & Current on all three phases.
b) Active/ Reactive Apparent Energy & Power
c) Maximum Demand/ Demand Forecasting
d) Time Bound & Stamped Data for KVAH/KWH/KVAR
With strict monitoring, accurate diagnostics of above parameters the following would be achieved effectively:
• Asset economic loading conditions identification and assessment for maximum practicable operating efficiency.
• Premature failures risk minimization.
• Life estimation and timely asset replacement/ retiring planning.
• Asset life extension by implementing correct operational and cost effective maintenance strategies
• Improvement in the system performance ensuring good reliability as well as plant availability.
• Minimization of the long-term operational cost.
• Cost saving by eliminating the unplanned maintenance.
• Minimizing the outage period.
• Relocation/ retirement planning.
• In time procurement of spare parts to get competitive rates.
• To enhance the overall reliability of the system
• Accurate risk assessment.
For recording and monitoring the real time date for above parameters we can take the help of online condition monitoring system for transformer, the typical schematic diagram is as below:
Above system are available with powerful software and having the various features some of them are as below:
Connectivity
Available through MODBUS, RS 485 & GSM/CDMA (Though Modem)
Inbuilt Software
Available & Suitable for Planning Preventive Maintenance Schedules, Asset Life Extension, Load Management and fault Monitoring
Data Storage
Data can be stored in graphical forms as well as time stamped forms
Suitable for all Voltage Class Transformers.
As we can see from above that online condition monitoring system are available with inbuilt software through which we can analyze the data and can plan our various activities which will help us in enhancing the life of transformer as well as reliability of equipment. With the help of above system we can observe 255nos. of transformer at a time. It will also benefit the end user to have power supply without interruption, in particular the industrial sector. It will reduce the risks to human kind and the environmental damages.
In case any enquiry feel free to contact us at:info@saielectricals.com
]]>
https://saielectricals.com/2015/08/site-instructions-for-transformers-part-5/feed/ 0
WHY Meerut is vibrant enough to become a smart city https://saielectricals.com/2015/07/why-meerut-is-vibrant-enough-to-become-a-smart-city/ https://saielectricals.com/2015/07/why-meerut-is-vibrant-enough-to-become-a-smart-city/#respond Thu, 16 Jul 2015 10:10:00 +0000 http://saielectricals.com/2015/07/16/why-meerut-is-vibrant-enough-to-become-a-smart-city/
By Girish Kumar
Keeping in view the aspirations of modern citizens, in todays world any city with a populations of 1.5 to 2.0 millions people will require smart city to live a life of Vibrancy. A smart city that is equipped with basic infrastructure to give high quality of life, a clean and sustainable environment through application of some smart solutions. Assured water and electricity supply, sanitation and solid waste management, efficient urban mobility and public transport, robust IT connectivity, e-governance and citizen participation, safety and security of citizens.Assured water and electricity supply, sanitation and solid waste management, efficient urban mobility and public transport, robust IT connectivity, e-governance and citizen participation, safety and security of citizens.
Meerut is the second largest city in National Capital region only after Delhi. Meerut could be one of the smart cities of India.
The city Meerut feels pride to stand fifth on the vibrancy index, declared by the US based financial company Morgan Stanley in the 2011 survey done on 200 cities of India. After examining it on their prescribed parameters the company adjudged its position ahead of Delhi and Mumbai in terms of investment and economic growth.
The Walled city Meerut has shown its existence from ancient period of Lord Rama and thereafter Kuru dynasty of Mahabharta which had privilege of having close association with Lord Krishna. The city also has pride of having some of the archeological site like Alamgirpur which existed parallel to Harrapa and Mohanjodaro. It also spearheaded the first war of Independence against British Raj in 1857.
SMART ENVIRONMENT
Besides being second largest city in National Capital Region (NCR) it also spearheaded the green revolution in the region in 1970s turning the region into an ‘agriculture belt’. The bumper crop of Sugarcane and potato year after year has paved the way of setting up many sugar mills and food processing plants in the region.
The trade of frozen meat flourished in the region in past one decade and many of international brands of frozen meat belong to this city which has been earning a good amount of foreign currency for country`s exchequer.

SMART ECONOMY
The city also has earned name in the manufacturing of sports goods especially world`s top cricket brand SG, SS and BDM have originated from this walled city. Engineering industry is another emerging commerce in the city. Known for its fine work of scissors manufacturing it has earned certification of geographic indicator patent in the name of ‘MEERUT SCISSORS’. This for the first time that traditional manufacturing activity has earned GI Patent in India.
Originalspecial taste of ‘Rewari and Gajak’ which is now choice of millions across the globe. 


SMART PEOPLE
Education and language play a significant role in the development of a city and Meerut is quite fortunate in the way that even after experiencing brunt of many communal riots in past people of different communities have shown their zeal to live and advance on the path of development together.
City peoples` die hard’ attitude also makes it a fit case to put it in a path of development for better future of their coming generation and country as well.
With more than three dozen engineering colleges and over 70 public schools the city has emerged as hub of education. This has given the city youngsters who are well versed in English language which helps in connecting them with rest of the world and easy access to information on internet. The city also has advantage of having four universities including one agriculture university and two medical colleges.
Its skilled artisans are a major demographic advantage for engineering industry while industrialists and entrepreneurs enjoy a cordial relationship which is evident by the fact that the city has experience no ‘labour unrest’ in past fifteen years.
It is a virgin place for industrial development and 12% of its land is available for industrial use along with the advantage of low cost as compared to other places of NCR. Seeing the potential of development GAILGAS Ltd. has made its elaborate setup in the district in order to provide clean and green piped gas fuel to industries for better development of the area. Food proccesssing industries have advantage of low cost of inputs in terms of fuel as well as agriculture produce.

SMART LIVING
The people and the culture of Meerut has promoted harmony and balance between the science and technology of the modern world we live in and the beauty and purity of the natural world that surrounds us. The city is resource rich in terms of the quality of soil available for growing organic agricultural food as also this becomes possible because of the availability of less contaminated Ganga water. 
SMART MOBILITY
In a quest to develop the city as new center of development the city is likely to get share of infrastructure projects of over Rs 20,000 crore in coming years These projects include Meerut Delhi express way, Rapid Rail Transit System, Bulandshahr- Meerut express way, Western Peripheral Expressway, Eastern Peripheral Expressway, Upper Ganga Expressway, Airport, Delhi Mumbai Freight Corridor, Amritsar Howrah freight Corridor etc.
Meerut stands thorough on the five pillars of a smart city which are smart economy, smart people, smart environment, smart mobility and smart living. All that we need is smart governance.
(The author is an entrepreneur Graduated from IIT, Kanpur, entrepreneur and activily associated with Industrial Association like CII, IIA, FISME, ITMA AND MIDFo)
In case any enquiry feel free to contact us at:info@saielectricals.com
]]>
https://saielectricals.com/2015/07/why-meerut-is-vibrant-enough-to-become-a-smart-city/feed/ 0